Battery Monitoring( Partnered with Albercorp )

A battery monitor can detect developing problems long before a critical situation develops by measuring and recording values during the installation and to look for trends over time. Changes in values over time, even though they may be within the manufacturer’s allowable ranges, may be cause for concern and may require action.

Complete and Customizable Monitoring Solution with No Interruptions

Design: ​With over 100 Possibilities of battery cabinet designs.  Alliance Power Services perform a site survey/walkthrough to identify the following areas:

  • Cabinet configuration
  • Installation Location of Hardware
  • Inspect for Objects in the overhead that may alter the installation (Existing Facilities)
  • Network Options to monitor via MODBUS

Installation: Alber trained from the factory, Alliance Power Services will perform the installation from start to finish.  No 3rd party sub contractors.

  • Panduit Runs
  • MODBUS Communications
  • LAN / Network Interface.  


Commissioning:  Commissioning / Start Up performed on equipment. 

  • Cell Voltage calibrations to battery specifics
  • Ambient temperature of battery cabinets
  • Test Current calibrations for Alber DC (Patent) Resistive Load Testing
  • Configuration of Database on Alber BMDM (Battery Monitor Data Manager) Platform (Legacy Product)
  • Configuration of Database on Alber Battery Explorer (Enterprise) New Product.
  • Training for onsite personnel – Alber BMDM Software, Alber Battery Monitor Training


Service:   Preventative Maintenance

  • Yearly calibrations to all parameters on the Alber software for each battery configuration
  • Annual Discharge test utilizing Alber BCT -2000 (Battery Capacitance Testing)
  • Alliance Power Services stock piles on hand spares for BDS-256XL and BDS-40 Controller and DCM’s  


Remote Reporting:  detailed monthly, quarterly, bi-annual or annual analytics reports

  • Individual Cell Voltage and ​Individual Cell Resistance – Health of the battery
  • Number of Discharges per month
  • UPS Float Current (Trickle Charge) to the batteries.  High Float Current is an indication of Thermal Runway
  • Battery Cabinet Ambient Temperatures.  High Temperature is an indication of Thermal Runway

Alber Battery Monitoring Options Designed to Meet your Operational Needs

Alber Battery diagnostic systems (BDS) continuously monitor all critical battery parameters, verify the integrity of the connected battery system, and alarm on any out-of-tolerance condition. Testing includes proactive, internal DC cell resistance measurements at programmed intervals recommended by IEEE standards. By tracking increases in internal cell resistance, the BDS predicts if the battery system will perform during a power outage.